Plastic Manhole Insert
Manhole Insert- V2P
Stainless Steel Insert
Valve Box Insert
Odoreater Insert
Inflow Cost Analysis
Leak Stopping
Patching / Invert Repair
Linings / Coatings
Infiltration Case Study








|
|
|
PARSON
CA LINER 100+
|
Calcium Aluminate lining designed to protect new
and existing structures against H2S attack.
| DESCRIPTION:
PARSON CA LINER 100+ is a high strength, pure fused Calcium Aluminate Cement and Calcium Aluminate aggregate mortar designed to rehabilitate and protect new and existing manholes, wet wells,
lift stations and other Wastewater related structures against
H2S attack. |
ADVANTAGES:
- Cost-effective alternative to replacement
- Stops infiltration and exfiltration
- Restores strucural integrity
- Provides a high level of corrosion protection
- High early and 28 day strengths
- Freeze-thaw resistant
- Low Permeability
- Excellent Bond to damp surfaces
- Apply up to 2" in a single coat
- Spincast, Spray Gun or trowel application
|
 |
Application
Equipment for Manhole Rehabilitation Products
PHYSICAL PROPERTIES:
Compressive Strength
ASTM C-109
Flexural Strength ASTM C-293
Tensile Strength ASTM C-190
Shear Bond ASTM C-882
Density |
24 hours 6,000 psi 28 days > 9,000 psi
24 hours 1,400 psi
28 days > 1,600 psi
28 days > 800 psi
>2,400 psi
150 pcf |
Shrinkage ASTM C-157
Freeze/Thaw ASTM C-666
Chloride Permeability
AASHTO T-277
Sulfide Resistance ASTM C-267 |
0.0% (at 90% RH)
300 cycles, No damage
< 300 coulombs (very low)
No weight loss after 90 days in 20,000 ppm aqueous sulfuric acid solution.
|
SURFACE PREPARATION: Thoroughly
clean and remove any loose or foreign materials including paints, dirt,
oil, grease, surface coatings, laitance and any other bond-inhibiting material
from surface to be coated, using minimum 3500 psi waterblast. Stop all active
leaks. (Please refer to our Manhole Rehabilitation Specifications for product
selections.) Surface should be Saturated Surface Dry (SSD) just prior to
material application. Any standing water must be removed. Please refer to
our Specifications for Manhole Rehabilitation for product selections.
MIXING: Using a slow-speed mortar mixer or large mechanical jiffy mixer, add approximately 3/4 gallon
of clean, potable water per 50 lb. bag of PARSON CA LINER 100+. Add water
to mixer and then add powder. Mix thoroughly for approximately 3
minutes until a uniform consistency has been obtained.
| APPLICATION: Using low pressure spray equipment or trowel, apply mixed product on vertical, horizontal and overhead surfaces to a minimum thickness of ½".
Trowel or brush to a smooth finish as soon as possible, but within one hour.
If additional material is required, apply up to 2” of product within
2-3 hours, then trowel or brush to a smooth finish as soon as possible,
but within one hour. Do not apply to frozen surfaces. As temperatures rise
above 80º F, the working and cure times will decrease. Conversely,
working and cure times will increase as temperatures fall below 65º
F. Equipment and hoses should be cleaned frequently of residual material. |

Click to watch application video |
COVERAGE: Approximately 10 sq. feet per 50 lb. bag at a thickness
of 1/2 inch.
PACKAGING: Available in 50 lb. multiwall paper bags with moisture
barrier.
STORAGE: Shelf life is 2 years when stored at 70°F in unopened,
tightly sealed bags in a dry area.
PRECAUTIONS: See MSDS for specific instructions. Use protective eye
wear, cover exposed skin and use breathing protection.
BACK TO TOP |