Plastic Manhole Insert
Manhole Insert- V2P
Stainless Steel Insert
Valve Box Insert
Odoreater Insert
Inflow Cost Analysis

Leak Stopping
Patching / Invert Repair
Linings / Coatings
Infiltration Case Study

Printable Version  

PARSON
SEAL-TITE


Fast reacting, rapid expansion grout for high volume leak repair


DESCRIPTION:
    PARSON SEAL-TITE is a moisture-insensitive, two component, fast reacting hydrophobic polyurethane grout designed to stop high volume active leaks in Manholes, Pump Stations and other Wastewater Structures. PARSON SEAL-TITE is packaged in a dual cartridge with a static mixer and is injected at or near the source of the leak, using a manual dual component caulk gun. The product contains no solvents, CFC’s or HFC’s.

ADVANTAGES:
  • Cures to a dense, rigid mass in approximately 30 seconds
  • Chemically Resistant
  • Can fill large holes and voids
  • Stops leaks up to 50gpm
  • Will not shrink
  • Non Hazardous - 100% Solids
  • Environmentally Friendly
  • Excellent Bond Strength

PHYSICAL PROPERTIES
Viscosity

Density    (Free Rise)
              (Confined)
Shrinkage
Compressive Strength
Tensile Strength
Shear Strength
Water Absorption
Elongation
Reaction Time
Expansion Time
A-200 cps @77°F
B-800 cps @77°F
4 lbs/cu. ft.
20 lbs/cu. ft.
0% after 90 days
100 psi
105 psi
75 psi
<1% by volume
5%
3 - 5 seconds
30 seconds
Brookfield Method

ASTM D-1622


ASTM D-1621
ASTM D-638
ASTM C-273
ASTM D-2172
ASTM D-1623

APPLICATION: Drill one 5/8” hole above the leak and on a 45 degree angle in order to intersect the leak point. The hole must penetrate through the structure wall. Remove one package from the carton, which contains one dual cartridge and one static mixer. Remove the black screw cap and two half-caps from the top of the dual cartridge. Slide the black screw cap over the end of the static mixer and screw into the top of the dual cartridge until tight. Place the dual cartridge, with static mixer attached, into the manual dual component caulk gun with the dual cartridge label facing up. Place approximately one-half of the static mixer into the drilled hole. Squeeze the dual component caulk gun trigger repeatedly to release material until both cartridges are completely empty, which should take less than 15 seconds. Immediately unscrew the black screw cap from the dual cartridge. Allow PARSON SEAL-TITE to cure for 5 minutes, then cut-off the static mixer flush with structure wall. Properly dispose of the used dual cartridge and static mixer.

PRECAUTIONS: PARSON SEAL-TITE reacts very quickly. It is important to remove ALL material from both tubes within 15 seconds.

SAFETY: Wear protective eyewear and headgear and cover all exposed skin. Follow appropriate OSHA requirements and procedures for confined space entry. Refer to container label for First Aid procedures. See MSDS for specific instructions.

STORAGE: Shelf Life is 3 years in original unopened containers stored in a dry environment at 70°F.

PACKAGING: PARSON SEAL-TITE is available in cases containing 6 individually packaged 22 oz. Dual Cartridges + 1 Static Mixer.

BACK TO TOP